Installation and operating manual

PFA Lined Sight Glass

Videron9 · transport, installation, operation and maintenance — read before you start.

Document
GFT9-VID-UM-001
Revision
Rev. J · 2026-11-19
Language
English
Manufacturer
GFT9 · Kempen, Germany
PFA Lined Sight Glass

1 Technical Data

1.1 Manufacturer Information

GFT9
Hooghe Weg 16, 47906 Kempen, Germany
Email: sales@gft9.shop
Web: https://gft9.shop
Phone: +49 2152 9148591

1.2 Product Overview

Parameter Value
Name Videron9
Design norm DIN/ISO | ANSI
Size DN 15-200 | NPS ½"-8" (larger sizes on request)
Flange dimensions EN 1092-1 (PN 16) | ASME B16.5 (Class 150, RF)
Face to face dimensions EN 558-1 Series 1
Lining PFA, PFA/AS; other linings on request
Body 1.0619 or 1.4408 / 1.4409 (A216 WCB, CF8M / CF3M)
Pressure 16 bar to 100 °C, 11 bar at 150 °C · DN 150–200 / NPS 6–8: PN 10 (10 bar) · see P-T diagram
Temperature range −60 °C up to 150 °C (12 bar below −10 °C with the 1.0619 body)
Custom FEP foil liner between glass and medium; coatings
Certificates EU Pressure Equipment Directive 2014/68/EU

1.3 Type plate, conformity and body markings

GFT9_Example_Nameplate

Type Plate
The stainless steel name plate is permanently riveted to the body. If the operator adds their own marking, they must make sure that the valve is suitable for the application concerned.

Body identification:
In accordance with DIN EN 19 and AD 2000 A4, the body is marked with:

  • Nominal size
  • Pressure rating
  • Body material
  • Manufacturer's mark
  • Melt number/Foundry identification
  • Foundry date

1.4 Weight DIN | ANSI

Weights are listed with the dimensions in Section 10. They are indicative; accurate weight on request.

1.5 Screws: Tightening Torque

Grease all screws and tighten them in diametrically opposite order!
The tightening torques stated for pipe screws and body screws must not be exceeded. An exception is described in Section 8, under 'Flange connection valve/pipe is leaking'. Recommended tightening torques are listed below.

1.5.1 Pipe Screws DIN | ANSI

DIN Pipe Screws
Size Screws Tightening Torque [Nm] — greased
DN 15 4 x M12 6
DN 20 4 x M12 8
DN 25 4 x M12 10
DN 40 4 x M16 20
DN 50 4 x M16 26
DN 80 8 x M16 25
DN 100 8 x M16 35
DN 150 8 x M20 65
DN 200 12 x M20 100
ANSI Pipe Screws
Size Screws Tightening Torque [in-lb / Nm] — greased
NPS ½" 4 x ½“ 45/5
NPS ¾" 4 x ½“ 55/6
NPS 1" 4 x ½“ 70/8
NPS 1½" 4 x ½“ 135/15
NPS 2" 4 x ⅝“ 220/15
NPS 3" 4 x ⅝“ 400/45
NPS 4" 8 x ⅝“ 310/35
NPS 8" 8 x ¾“ 1020/115

1.5.2 Body / Window Screws (per window) DIN | ANSI

DIN Body / Window Screws (per window)
Size Screws Tightening Torque [Nm / in-lb] — greased
DN 15 4 x M12 50/443
DN 20 4 x M12 50/443
DN 25 4 x M12 50/443
DN 40 4 x M16 65/575
DN 50 4 x M16 65/575
DN 80 6 x M16 65/575
DN 100 6 x M16 65/575
DN 150 6 x M16 65/575
DN 200 6 x M16 65/575
ANSI Body / Window Screws (per window)
Size Screws Tightening Torque [in-lb / Nm] — greased
NPS ½" 4 x M12 443/50
NPS ¾" 4 x M12 443/50
NPS 1" 4 x M12 443/50
NPS 1½" 4 x M16 575/65
NPS 2" 4 x M16 575/65
NPS 3" 6 x M16 575/65
NPS 4" 6 x M16 575/65
NPS 6" 6 x M16 575/65
NPS 8" 6 x M16 575/65

1.6 Pressure Temperature Diagram

Sight Glass — pressure-temperature diagram

P-T diagram with vacuum range: 16 bar −10 … 100 °C, 11 bar at the 150 °C glass limit · DN 150–200 / NPS 6–8: PN 10 · −60 °C at 12 bar (AD 2000-Merkblatt W 10) · one diagram for 1.0619, 1.4408 and 1.4409 bodies · full vacuum (1 mbar abs) to 100 °C

2. Notes on safety

Read this manual before installing and commissioning the valve. It contains the essential instructions for installation, operation and maintenance.
Keep the manual where the valve is in use, so that staff can refer to it at any time.
For use in potentially explosive atmospheres, also follow Section 3.
Only qualified personnel may install, operate and service the valve.
The operator must define the staff's responsibilities and authority and how the staff are supervised.

Every warning and sign on the sight glass itself must be followed and kept fully legible.
Disregarding these safety instructions can void all claims for damages.

It can also lead, for example, to the following hazards:

  • Loss of essential functions of the valve or plant.
  • Danger to persons from electrical, mechanical and chemical effects.
  • Harm to the environment from escaping hazardous substances.
Hazard_Sign_PFA_Lined_Valve_Manual

General hazard symbol!
Danger to persons.

Information_Sign_PFA_Lined_Valve_Manual

Safety symbol!
Disregarding this note can endanger the sight glass and its function.

2.1 Intended use

GFT9 sight glasses are designed for the passage of fluids. They are pressure-maintaining components as defined by the Pressure Equipment Directive (PED).

The Videron9 permit a view into the housing interior from two
opposite sides ans is only intended for horizontal installation. The sight glass is used for monitoring of flow, filling level, condition, color and gas contents of media in pipes and vessels and near pumps.
The valves are suitable for non-boiling liquids of group 1 in acc. with the Pressure Equipment Directive (PED). Solids in the medium can increase wear, damage the sealing faces or shorten the service life of the valve.

If the operating conditions are to differ from those the valve was ordered for, the operator must carefully check that design, materials and accessories still suit the new application. (Consult the manufacturer.)

2.2 For the customer / operator

The operator is responsible for ensuring that:

  • hot or cold valve parts are guarded against accidental contact
  • the valve is correctly installed in the pipeline
  • flow velocities in continuous service stay within the normal limits for the line.
  • an appropriate collection system is used to contain drip leaks/leaks locally and harmlessly.

These points are not the manufacturer's responsibility.

The design does not take seismic loads into account.

Fire protection to DIN EN ISO 10497 cannot be provided, because the lining and other components are made of plastic.

2.3 Improper operation

Safe and reliable operation depends on using the valve only as described under Intended use (Section 2.1).

Hazard_Sign_PFA_Lined_Valve_Manual

The operating limits given on the name plate or in the pressure-temperature diagram must never be exceeded.

3. Use in potentially explosive atmospheres

The valve has no electrical parts and no drive of its own (an actuator is an attachment). Its surface temperature is determined by the medium (and, on heated valves, by the heating medium). The valve carries no ATEX marking.

This manual does not give a general approval for use in potentially explosive atmospheres. Whether the valve may be used in such an area is decided for the specific application, in the operator's own assessment of the zone, the gas or dust group, the temperature class and the electrostatic behaviour of the medium.

GFT9 supports this assessment for a concrete application. On request we provide the design data needed for it — materials, lining type (standard or antistatic), earthing path, exposed non-conductive surfaces — and review the case with you. Contact: sales@gft9.shop.

Points the assessment must cover (from experience with lined valves; not a complete list):

  • Earthing of the valve, e.g. tooth lock washers under the pipe screws or an earthing cable (Section 6, Grounding).
  • Chargeable media (conductivity below 10⁻⁸ S/m): charge can build up on a standard lining; an antistatic lining (PFA/AS: surface resistance below 10⁹ Ω, leakage resistance below 10⁶ Ω) leads it away. With a standard lining the valve must stay completely filled or the atmosphere inside must be inerted; non-antistatic parts can limit the permitted zone and gas group.
  • Exposed non-conductive surfaces, e.g. lining at the flange faces or a sight-glass window.
  • Medium temperature and heating-medium temperature against the temperature class.
  • Actuators, positioners, limit switches, solenoid valves, sensors and heating jackets: their own explosion-protection conformity, per their manuals.
  • Abrasive media and dust deposits on the outside: inspection and cleaning intervals.
  • Plastic-lined valves must not be used with carbon disulfide.
  • No moving parts.
  • Glass and liner are non-conductive and cannot be earthed.

WARNING — Ignition from improper use. Overheating, electrostatic charge or sparks can arise if the valve is used outside its intended use. → Use the valve only as described in this manual and as confirmed in the assessment for your application.

4. Safety note for TA Luft (Clean Air Act) versions

A TA Luft certificate is held for the Spheron9 ball valve. For other valves a TA Luft version is available on request. Any TA Luft certificate or manufacturer declaration is valid only if these operating instructions have been read and are followed.

  • Maintain the valve at regular intervals, check that the bolted connections are tight and retighten them where necessary.

5. Transport, storage and disposal

Handle the goods carefully in transit. Protect the valve from knocks and impacts while it is being transported.

Immediately on receipt, check that the consignment is complete and free of transport damage.

Take care not to damage the protective paint coat.

Hazard_Sign_PFA_Lined_Valve_Manual

Carry out all transport work in line with recognised good engineering practice and the accident prevention regulations.

Information_Sign_PFA_Lined_Valve_Manual

The valve is delivered with flange caps fitted. They keep dirt off the plastic surfaces and protect them from mechanical damage. Remove them only immediately before installation.

5.1 Storage

Valves that are not installed straight away must be stored correctly.
Store them in a dry, well-ventilated room free of vibration, at a temperature that is as constant as possible.
Keep elastomer parts out of UV light.
As a rule, the valves should not be stored for more than 10 years.

5.2 Return consignments

A safety information sheet / general safety certificate stating the field of application must always be enclosed with any return consignment.
Contact the Manufacturer for more Information in that regard.
The safety precautions and decontamination measures must be stated.

Hazard_Sign_PFA_Lined_Valve_Manual

Valves that have handled aggressive or toxic media must be rinsed and cleaned before they are returned to the manufacturer's works

5.3 Disposal

Parts of the valve may carry medium residues that are harmful to health and the environment; cleaning alone is therefore not enough.

Hazard_Sign_PFA_Lined_Valve_Manual

The medium can injure people and harm the environment!

Wear suitable personal protective equipment for all work on the valve.
Before disposing of the valve:

  • Collect any escaped medium or other substances and dispose of them according to local regulations.
  • Neutralise medium remaining in the valve.
  • Sort the valve materials by type (plastics, metals, etc.) and dispose of each according to local regulations.

6. Installation

Check the valve for transport damage on receipt. Do not install a damaged sight glass.

  • Clean the valve and the adjoining pipework thoroughly before installation, removing all dirt and in particular hard particles.
  • Install the valve free of stress between aligned pipes, and tighten the bolts to the correct torque.

6.1 Flange caps and gaskets

Leave the flange caps on until the valve is about to be installed.

If the plastic sealing faces are at particular risk of damage, for example from metal or enamelled mating flanges, PTFE-lined gaskets with metal inserts are recommended. Contact the Manufacturer for further discussion.

6.2 Direction of flow and installation position

Install the valve in the correct direction of flow. An arrow on the valve body shows the direction.

6.3 Grounding

The valve must be grounded. The simplest way is to fit tooth lock washers under the pipe screws. Fit them under one pipe screw on each flange.

Upon customer request a set screw M6 is attached to each flange with a hex nut and washer as an additional earthing connection.

If this is not possible, grounding must be provided another way, e.g. with an earthing cable.

6.4 Test pressure

The test pressure PT must not be higher than 1.5 x PS(PN), with PS(PN) as stated in the valve marking.

7. Operation

7.1 Initial commissioning

The valves are normally leak-tested with air or water at the factory. Check the cover screws before commissioning. For tightening torques, see Section 1.5!

When the valve reaches operating pressure and temperature for the first time, retighten all bolted joints to prevent leaks. For tightening torques, see Section 1.5.

Hazard_Sign_PFA_Lined_Valve_Manual

Unless dry delivery was agreed, some water may remain in the flow passage of the valve. This water may react with the medium.

7.2 Improper operation and their consequences

  • Prevent the medium from crystallising, for example by heating.
  • Solids in the medium increase wear.
  • Operating outside the pressure-temperature diagram can damage the valve.
Hazard_Sign_PFA_Lined_Valve_Manual

Before undoing the flange connection, make sure that the plant has been depressurised and emptied!

Hazard_Sign_PFA_Lined_Valve_Manual

Before undoing the flange connection, make sure that the plant has been depressurised and emptied!

7.3 Shutdown

Comply with the local regulations when dismantling the valve!

As soon as the valve has been removed, fit flange caps to protect the flanges from mechanical damage. See also Section 6.1.
Lock out remote-controlled actuators so that they cannot start unexpectedly.

8. Malfunctions

Flange connection valve/pipe is leaking

  1. Retighten the flange screws to the torque given in Section 1.5.1.
  2. If the joint still leaks, the screws may be tightened up to 10% above the recommended torque.
  3. If the leak persists, dismantle the valve and inspect it.

Glass clouded or coated from the inside

  1. Deposits, crystallisation or a product film on the glass (Section 7.2).
  2. Make sure that the plant is depressurised and emptied (Section 7), then clean the glass from the inside (Section 9). Use mild detergents.

Glass etched or milky (transparency lost permanently)

  1. The medium attacks the borosilicate glass, e.g. hydrofluoric acid and other media that attack glass.
  2. Have the glass (Pos. 3) replaced — contact the manufacturer.
  3. For such media use the FEP foil liner option, which keeps the glass out of contact with the medium.

Glass cracked or chipped

  1. Take the sight glass out of service immediately: isolate, depressurise and drain it (Section 7.3). Never operate it with a damaged glass.
  2. Replace the glass (Pos. 3) and the sealing-paper gasket (Pos. 4), see Section 9.2.
  3. Possible causes: window screws tightened unevenly or above the torque in Section 1.5.2, thermal shock, impact, or pipe forces on the body. Tighten the window screws crisscross and evenly (Section 9.3) and install the sight glass free of tension (Section 6).

Leak at the window frame (glass seal)

  1. Cold and depressurised: retighten the window screws crisscross and evenly, in 10 Nm steps, up to the torque in Section 1.5.2 (Section 9.3).
  2. Never exceed that torque. The 10 % allowance for the flange screws does not apply to the window screws: the glass risks cracking.
  3. If the leak persists, replace the sealing-paper gasket (Section 9.2) and check the glass and the PFA lining seat for damage.

Condensation or ice on the outside of the glass

  1. Normal with cold media; not a leak.
  2. Insulate or heat the surroundings if a clear view is needed.

FEP foil blistered, torn or clouded (option)

  1. A damaged foil no longer protects the glass: check the glass for etching.
  2. Replace the FEP foil when the glass is serviced (Section 9.2). If the damage recurs, contact the manufacturer with the operating data.

9. Maintenance

Before you start

  1. Make sure that the plant is depressurised and emptied before undoing any connection (Section 7).
  2. Parts of the valve may carry medium residues (Section 5.3). Wear suitable personal protective equipment for all work on the valve (Section 5.3).
  3. As soon as the valve is out of the line, fit flange caps to protect the flanges from mechanical damage (Section 6.1).
  • Repairs may only be carried out by qualified staff with suitable tools.
  • The sectional drawing in Section 11 shows the position, name and item number of every part of the valve.
  • When ordering spare parts, quote all data from the valve identification.
  • Use genuine GFT9 spare parts only.
  • To avoid leaks, check the bolted connections regularly, at intervals suited to the operating conditions.
  • For tightening torques, see Section 1.5

Hazard_Sign_PFA_Lined_Valve_Manual

Make sure that when working on the sight glass it is drained. See also Section 7.3

9.1 Cleaning the glass

  • Clean the glass from the outside as required, with mild detergents.
  • Clean the glass from the inside as required. The sight glass must be depressurised and drained first (Section 7.3).

9.2 Replacing the glass and the gasket

Order of the parts, from the outside in (positions as in Section 11): hex screws with washers (5), window frame (2), sealing-paper gasket (4), sight glass (3), FEP foil (6, option), PFA lining of the body (1). The sealing-paper gasket sits between the window frame and the glass; the glass rests on the PFA lining. If an FEP foil is fitted, it lies between the glass and the PFA lining and protects the glass from the medium.

  1. Isolate, depressurise and drain the sight glass (Section 7.3) and let it cool down. Wear eye protection and gloves.
  2. Unscrew the hex screws crisscross, a little at a time, and remove them with their washers.
  3. Lift off the window frame.
  4. Remove the sealing-paper gasket.
  5. Take the glass off the PFA lining. If fitted, remove the FEP foil.
  6. Clean the seating faces of the window frame and the PFA lining without scratching the PFA. Never refit a cracked, chipped or etched glass; always fit a new sealing-paper gasket.
  7. Reassemble in reverse order: the FEP foil (if used) on the PFA lining, the glass centred on the lining, the sealing-paper gasket, then the window frame.
  8. Fit the washers, screw in the hex screws by hand, then tighten them crisscross in 10 Nm steps up to the torque in Section 1.5.2 (Section 9.3).
  9. Before returning to service, check the window joint for leaks. The test pressure must not exceed 1.5 × PS (Section 6.4).

9.3 Tightening the window screws

Tighten the window screws evenly, so that the clamping force builds up steadily and evenly over the whole glass. Uneven tightening loads the glass on one side and the glass risks cracking.

  1. Screw in all window screws by hand until they touch the window frame.
  2. Tighten crisscross (diametrically opposite screws one after the other) to 10 Nm.
  3. Raise the torque in steps of 10 Nm (20, 30, 40 Nm …), one full crisscross round per step.
  4. Finish with one crisscross round at the final torque in Section 1.5.2: M12 50 Nm, M16 65 Nm.
  • Window screws: 4 screws up to DN 65 / NPS 2½", 6 screws per window (12 per sight glass) from DN 80 / NPS 3"; M12 up to DN 25 / NPS 1", M16 from DN 40 / NPS 1½". Torques: Section 1.5.2.
  • Never exceed the torque in Section 1.5.2, not even to stop a leak.
  • After the first loading with operating pressure and temperature, check the window screws again, cold and depressurised (Section 7.1).

10. Dimensional Drawings

10.1 Dimensional Measurements DIN

Sight Glass — dimensional drawing
Size L H d (RF) k D n × ØB Øa Weight (indicative)
DN 15 130 mm 125 mm 45 mm 65 mm 95 mm 4 x 14 (M12) 32 mm 3 kg
DN 20 150 mm 125 mm 58 mm 75 mm 105 mm 4 x 14 (M12) 32 mm 4 kg
DN 25 160 mm 140 mm 68 mm 85 mm 115 mm 4 x 14 (M12) 48 mm 5.5 kg
DN 40 200 mm 170 mm 88 mm 110 mm 150 mm 4 x 18 (M16) 65 mm 9.6 kg
DN 50 230 mm 194 mm 102 mm 125 mm 165 mm 4 x 18 (M16) 80 mm 12.5 kg
DN 80 310 mm 215 mm 138 mm 160 mm 200 mm 8 x 18 (M16) 100 mm 25.5 kg
DN 100 350 mm 270 mm 158 mm 180 mm 220 mm 8 x 18 (M16) 125 mm 31.5 kg
DN 150 480 mm 295 mm 212 mm 240 mm 285 mm 8 x 22 (M20) 142 mm 68 kg
DN 200 600 mm 345 mm 268 mm 295 mm 340 mm 12 x 22 (M20) 190 mm 88 kg

Indicative weights, in line with body volume. Accurate weight on request: sales@gft9.shop.

10.2 Dimensional Measurements ANSI

Sight Glass — dimensional drawing
Size L H d (RF) k D n × ØB Øa Weight (indicative)
NPS ½" 130 mm 125 mm 34.9 mm 60.3 mm 88.9 mm 4 x 15.9 32 mm 3 kg
NPS ¾" 150 mm 125 mm 42.9 mm 69.8 mm 98.4 mm 4 x 15.9 32 mm 4 kg
NPS 1" 160 mm 140 mm 50.8 mm 79.4 mm 108 mm 4 x 15.9 48 mm 4.8 kg
NPS 1½" 200 mm 170 mm 73 mm 98.4 mm 127 mm 4 x 15.9 65 mm 8.8 kg
NPS 2" 230 mm 194 mm 92.1 mm 120.7 mm 152.4 mm 4 x 19.1 80 mm 11.5 kg
NPS 3" 310 mm 215 mm 127 mm 152.4 mm 190.5 mm 4 x 19.1 100 mm 22 kg
NPS 4" 350 mm 270 mm 157.2 mm 190.5 mm 228.6 mm 8 x 19.1 125 mm 28.8 kg
NPS 6" 480 mm 295 mm 216 mm 241.3 mm 279.4 mm 8 x 22.2 142 mm 62 kg
NPS 8" 600 mm 345 mm 269.9 mm 298.5 mm 342.9 mm 8 x 22.2 190 mm 82 kg

Indicative weights, in line with body volume. Accurate weight on request: sales@gft9.shop.

11. Sectional Drawing

Sight Glass — sectional drawing with parts list positions
Pos. Item Material
Lining PFA, PFA/AS; other linings on request
1 Body 1.0619 or 1.4408 / 1.4409 (A216 WCB, CF8M / CF3M)
2 Window Frame (Cover Plate) 1.0619 (A216 WCB), 1.4308, 1.4408 (CF-8M)
3 Glass Borosilicate Glass (DIN 7080)
4 Sealing Paper Fibre gasket sheet, 2 mm
5 Hex Screws with Washers Stainless steel A2 or A4; other materials on request
6 FEP Foil (option) FEP, 1 mm

12. Declaration of Conformity

The EU declaration of conformity for this product is supplied with every delivery and is available on request: sales@gft9.shop.

The product is designed and manufactured in accordance with the Pressure Equipment Directive 2014/68/EU.