Clean room corridor with stainless chemical supply cabinets and an operator in a gown in the background

Clean Rooms & High-Purity Chemical Supply

PFA-Lined Stainless Steel Valves and Components for Clean Rooms

PFA inside, electropolished stainless steel outside — planned with you, built to your line

In a clean room, a valve has two jobs: keep aggressive chemicals contained, and have no painted surface in the room.

GFT9 Clean Room Series valves pair a PFA-lined wetted path with an electropolished stainless steel body in 1.4408 (CF8M). There is no paint to chip or flake, and the wetted path is PFA.

The series covers the Spheron9 ball valve, Videron9 sight glass, Provaron9 sample valve, Imperium9 control valve, Prohibron9 ball check valve, Membron9 diaphragm valve and Purion9 strainer.

Where a standard part does not fit, we plan the component with you from scratch — special connections, lengths and geometries, in stainless steel or other alloys — and build it in our own lining shop, from single pieces and small batches to series.

View the Clean Room Series →

Why PFA

Why PFA and Stainless Steel

One material against the medium. The wetted path is PFA-lined. Acids, alkalis, oxidisers and solvents used for etching, cleaning and dosing see the same fluoropolymer, so one valve design covers many chemicals.

No paint on the outside. Standard lined valves have painted carbon steel bodies. In a clean room, paint is a source of particles once it is scratched or ages. The Clean Room Series body is stainless steel 1.4408 (CF8M), electropolished instead of painted.

Documentation for regulated plants. Every valve is pressure-tested to DIN EN 12266-1 and ships with EN 10204 3.1 material certificates. For pharma and food-contact service, an FDA declaration for the PFA wetted parts and USP Class VI documentation are available on request.

Built to your drawing. Special connections, lengths and geometries on request — single pieces, small batches or series.

Applications

Where Our Components Are Used

Chemical distribution

Isolation, sampling and visual flow checks in the lines that supply acids, alkalis and solvents to tools and process equipment.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C · Videron9 sight glass, DN 15 – 250 · 16 bar · up to +150 °C · Purion9 strainer, DN 25 – 150 · 16 bar · up to +150 °C

Wet benches and process skids

Compact lined valves and custom lined fittings built into equipment by skid and tool manufacturers.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C · Prohibron9 ball check valve, DN 15 – 200 · up to 10 bar · up to +200 °C · Membron9 diaphragm valve, DN 15 – 150 · pressure and temperature per P-T diagram

Pharma and biotech utilities

Corrosive-media lines in production and laboratory areas — for example cleaning chemicals and pH adjustment.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C · Provaron9 sample valve, DN 25 – 80 · up to 16 bar · up to +150 °C · Imperium9 control valve, DN 15 – 100 · up to 16 bar · up to +180 °C

Sampling points

Sample valves for taking representative samples from lined lines without opening the system.

→ Provaron9 sample valve, DN 25 – 80 · up to 16 bar · up to +150 °C

Custom lined components — from prototype to series

Tees, reducers, spacers, special flanges and assemblies in sizes and geometries that are not in a catalogue.

→ Custom-made lined components

Chemical resistance

Typical media and PFA resistance

MediumFormulaConcentrationMax. temp.Rating
Hydrofluoric AcidHFUp to 49 %100 °C Excellent
Sulfuric AcidH₂SO₄Up to 98 %120 °C Excellent
Nitric AcidHNO₃Up to 70 %80 °C Excellent
Hydrogen PeroxideH₂O₂Up to 35 %60 °C Excellent
Ammonium HydroxideNH₄OHUp to 29 %60 °C Excellent
Isopropyl AlcoholC₃H₈OPure60 °C Excellent

PFA lining resists the acids, alkalis, oxidisers and solvents listed above; more media are in the PFA chemical resistance guide. Temperature limits shown are conservative for continuous service; the valve's own limit is its P-T rating. Contact us for your media and conditions.

Excellent full resistance, continuous service · Good suitable for most applications · Limited check the conditions with us. Ratings refer to the PFA lining; the valve's own pressure–temperature rating also applies.

Products

PFA-Lined Products for Clean Room Service

Clean Room Ball Valves — Spheron9

Clean Room Ball Valves — Spheron9

Full-bore ball valve with electropolished stainless steel body 1.4408 (CF8M), one-piece PFA-lined ball-stem and two-stage blow-out protection.

DN 15 – DN 200 / NPS ½" – 8" · up to 16 bar · −60 °C (1.4408 / 1.4409) up to +200 °C, see P-T diagram · TA-Luft leakage class BH (DN 10 – DN 150, certified −20 °C to +180 °C) · actuator mounting to EN ISO 5211.

View Clean Room Ball Valves →
Clean Room Sight Glasses — Videron9

Clean Room Sight Glasses — Videron9

Visual flow and fill-level control with a PFA-lined body in electropolished stainless steel 1.4408 (CF8M).

DN 15 – DN 250 / NPS ½" – 10" · 16 bar · −10 °C up to +150 °C, see P-T diagram.

View Clean Room Sight Glasses →
Clean Room Sample Valves — Provaron9

Clean Room Sample Valves — Provaron9

Sampling from lined lines with the wetted path in PFA and an electropolished stainless steel body 1.4408 (CF8M).

DN 25 – DN 80 / NPS 1" – 4" · up to 16 bar · −10 °C up to +150 °C, see P-T diagram.

View Clean Room Sample Valves →
Custom-Made Lined Components

Custom-Made Lined Components

Planned from scratch with your engineers and lined in-house — stainless steel or other alloys, single pieces, small batches or series.

Discuss a Custom Part →

Quality

Quality and Documentation

  • Every valve is tested before delivery to DIN EN 12266-1.
  • EN 10204 3.1 material certificates with heat numbers.
  • On request: FDA declaration for the PFA wetted parts; USP Class VI documentation.
  • Spheron9 ball valve: TA-Luft leakage class BH to DIN EN ISO 15848-1 (DN 10 – DN 150, certified −20 °C to +180 °C) and PED 2014/68/EU Module A2 with notified body 0035.
  • Made in Germany · country of origin Germany.

FAQ

Questions we are often asked

What is the GFT9 Clean Room Series?

PFA-lined valves with electropolished stainless steel 1.4408 (CF8M) bodies — no paint to flake, fluoropolymer on the wetted side: Spheron9 ball valve, Videron9 sight glass, Provaron9 sample valve, Imperium9 control valve, Prohibron9 ball check valve, Membron9 diaphragm valve and Purion9 strainer.

PFA or PTFE lining — what is the difference?

Both are fully fluorinated plastics with almost universal chemical resistance. PTFE cannot be melted, so PTFE liners are pressed and sintered. PFA can be melted, so we transfer-mould it into the valve body: the lining is dense, anchored in the body and follows complex shapes. If your specification says "PTFE-lined", a PFA-lined valve meets the same chemical duty — ask us for a comparison for your medium.

Which documents come with the valves?

Every valve is tested to DIN EN 12266-1 and ships with EN 10204 3.1 material certificates. Pressure-bearing products are designed and manufactured to PED 2014/68/EU; the Spheron9 ball valve is additionally certified under Module A2 and type-tested to TA-Luft. On request we add an FDA declaration for the PFA wetted parts and USP Class VI documentation.

Which Clean Room Series valve goes where?

Isolation: Spheron9 ball valve, DN 15 – 200, up to 16 bar. Flow check: Videron9 sight glass, DN 15 – 250. Sampling: Provaron9 sample valve, DN 25 – 80. Regulation, backflow protection, throttling and straining: Imperium9, Prohibron9, Membron9, Purion9. All have an electropolished 1.4408 (CF8M) body. For parts not in the range, we plan the component with you.

Plan Your Clean Room Components With Us

Send us the medium, pressure, temperature, connection standard and quantity — or a sketch of the part you need. We will tell you what fits from the range and what we would build for you.

We work with fab and plant operators, skid and tool manufacturers, and the contractors who install chemical supply systems.

Email: sales@gft9.shop Phone: +49 2152 9148591

Related: Semiconductor wet processing · Pharma and biopharma · Fine chemicals and APIs

Request Quotation →

Contact form