Data center rooftop at dusk with rows of cooling towers and insulated chilled-water pipework

Data Centers

PFA-Lined Valves and Components for Data Center Cooling

Corrosion-free flow control for cooling-water treatment, liquid cooling loops and custom lined parts — from prototype to series

Every megawatt of compute ends up as heat, and more and more of it is carried away by water — through cooling towers, chilled-water plants and, increasingly, liquid loops that run directly to the chip. The chemistry that keeps cooling water clean is aggressive, and the loops that reach the chip tolerate no corrosion products at all.

GFT9 makes PFA-lined valves, strainers and custom lined components — made in Germany. The wetted path is PFA-lined; the carbon-steel or stainless body stays outside the medium.

For OEMs, skid builders and contractors we design custom lined parts, build the tooling in-house and produce them from a single prototype up to series.

Discuss a Custom Component →

Why PFA

Why PFA-Lined Equipment in Data Center Cooling

Cooling-water treatment. Open cooling towers are dosed with sodium hypochlorite as biocide — typically 10–12.5 % product — and with sulfuric acid to hold pH. Carbon steel, copper, brass, aluminium and galvanised parts are not suitable for hypochlorite service, and the two chemicals must run in separate lines. A fully PFA-lined valve or strainer handles both with the same design.

Liquid cooling loops. Cold-plate microchannels are blocked by particles and corrosion products. A PFA-lined wetted path does not corrode. Send us your cleanliness requirements for the loop.

Applications

Where GFT9 Products Fit in a Data Center

Cooling-tower chemical dosing

Isolation and check valves on hypochlorite and sulfuric-acid dosing lines; strainers protecting dosing pumps and injection points. Hypochlorite and acid stay on separate, fully lined lines.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C · Purion9 T-strainer, DN 25 – 150 · up to 16 bar · up to +150 °C · Prohibron9 ball check valve, DN 15 – 200 · up to 10 bar · up to +200 °C · Vibron9 swing check valve, DN 40 – 400 · up to 16 bar · up to +150 °C · Imperium9 control valve, DN 15 – 100 · up to 16 bar · up to +180 °C

Make-up water treatment

Acid and caustic lines for softening, demineralisation and RO pretreatment of the make-up water that feeds the cooling system.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C · Imperium9 control valve, DN 15 – 100 · up to 16 bar · up to +180 °C · Membron9 diaphragm valve, DN 15 – 150 · pressure and temperature per P-T diagram

Liquid cooling — CDU and secondary loops

Lined valves, strainers and fittings wherever the wetted path must stay metal-free and particle-free, including conductive PFA/AS lining where static charge has to be dissipated.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C

Custom lined components in series

Manifolds, tees, reducers, flow bodies and housings lined in PFA to your drawing. We design the part and the tool, build the mould in-house and transfer-mould the lining — from one prototype to series production. 3D models (STEP) for your integration are available on request.

Chemical resistance

Typical media and PFA resistance

MediumFormulaConcentrationMax. temp.Rating
Sodium HypochloriteNaOClUp to 15 %60 °C Excellent
Sulfuric AcidH₂SO₄Up to 98 %120 °C Excellent
Sodium HydroxideNaOHUp to 50 %120 °C Excellent
Hydrochloric AcidHClUp to 37 %120 °C Excellent
Ethylene / Propylene GlycolC₂H₆O₂ / C₃H₈O₂Glycol–water coolant mixtures100 °C Excellent
Deionised WaterH₂OPure120 °C Excellent

PFA lining resists the cooling-water treatment and coolant chemicals listed above; more media are in the PFA chemical resistance guide. Hypochlorite and acid are dosed through separate lines and are never mixed. Temperature limits shown are conservative for continuous service; the valve's own limit is its P-T rating. Contact us for your media and conditions.

Excellent full resistance, continuous service · Good suitable for most applications · Limited check the conditions with us. Ratings refer to the PFA lining; the valve's own pressure–temperature rating also applies.

Products

PFA-Lined Products for Data Center Cooling

PFA-Lined Ball Valves — Spheron9

PFA-Lined Ball Valves — Spheron9

Full-bore isolation with a one-piece PFA-lined ball-stem and two-stage blow-out protection.

DN 15 – DN 200 / NPS ½" – 8" · up to 16 bar · −10 °C (1.0619) or −60 °C (1.4408 / 1.4409) up to +200 °C, see P-T diagram · actuator mounting to EN ISO 5211 · body 1.0619 (A216 WCB) or 1.4408 (CF-8M).

View Ball Valve Range →
PFA-Lined Strainers — Purion9

PFA-Lined Strainers — Purion9

T-pattern strainers with full PFA lining and PTFE baskets protect dosing pumps, injection points and instruments from particles.

DN 25 – DN 150 / NPS 1" – 6" · PN 16 · −10 °C up to +150 °C.

View Strainer Range →
PFA-Lined Check Valves — Prohibron9 and Vibron9

PFA-Lined Check Valves — Prohibron9 and Vibron9

Prohibron9 ball check and Vibron9 swing check valves stop backflow on dosing pump discharges and protect chemical feed lines from reverse flow.

Prohibron9: DN 15 – DN 200 / NPS 1" – 8" · up to 10 bar · −10 °C up to +200 °C. Vibron9: DN 40 – DN 400 / NPS 1½" – 16" · up to 16 bar · −40 °C up to +150 °C.

View Check Valve Range →
Custom Lined Components

Custom Lined Components

Your part, lined in PFA: in-house design, in-house tool and mould making, and PFA transfer moulding — one prototype or a series. Send a drawing, a sample or a sketch.

Custom-Made Solutions →

Quality

Quality and Documentation

  • Every valve is tested before delivery to DIN EN 12266-1.
  • EN 10204 3.1 material certificates with heat numbers.
  • PFA-lined wetted path; conductive PFA/AS lining for antistatic service.
  • Spheron9 ball valve: TA-Luft leakage class BH (DN 10 – DN 150, certified −20 °C to +180 °C) to DIN EN ISO 15848-1 and PED 2014/68/EU Module A2 with notified body 0035.
  • Made in Germany · country of origin Germany.

FAQ

Questions we are often asked

Why lined valves in data center cooling-water treatment?

Cooling towers are dosed with sodium hypochlorite and sulfuric acid. Both attack carbon steel, brass and copper; PFA-lined valves keep the dosing lines tight. The two chemicals run in separate lines — never mixed.

PFA or PTFE lining — what is the difference?

Both are fully fluorinated plastics with almost universal chemical resistance. PTFE cannot be melted, so PTFE liners are pressed and sintered. PFA can be melted, so we transfer-mould it into the valve body: the lining is dense, anchored in the body and follows complex shapes. If your specification says "PTFE-lined", a PFA-lined valve meets the same chemical duty — ask us for a comparison for your medium.

Which documents come with the valves?

Every valve is tested to DIN EN 12266-1 and ships with EN 10204 3.1 material certificates. Pressure-bearing products are designed and manufactured to PED 2014/68/EU; the Spheron9 ball valve is additionally certified under Module A2 and type-tested to TA-Luft.

Which PFA-lined valve goes where in a cooling-water system?

Isolation on dosing lines: Spheron9 ball valve, DN 15 – 200. Dosing-pump discharges: Prohibron9 ball check valve, DN 15 – 200, or Vibron9 swing check valve, DN 40 – 400. Protection ahead of pumps and instruments: Purion9 T-strainer, DN 25 – 150. Dosing and pH control: Imperium9 control valve, DN 15 – 100.