Materials
Materials for PFA-lined valves
Virgin PFA, antistatic PFA/AS, PTFE and PTFE-carbon, body and trim metals, special alloys and ceramics — what each does and when to choose it.
Virgin PFA
Virgin PFA — the standard lining
PFA (perfluoroalkoxy alkane) is a fully fluorinated thermoplastic. It shares the chemical inertness of PTFE, but it melts and flows. That lets us transfer-mould it into the valve body. The lining is dense, anchored in the body and follows complex shapes. Because the lining is seamless and held by the steel over its whole surface, it is designed for vacuum service — a loose PTFE sleeve, held only at its flared ends, can pull away from the steel under vacuum. Every GFT9 valve line has virgin PFA as its standard lining. "Virgin" means unfilled, with no regrind.
In a PFA-lined valve the metal body carries the pressure and the lining carries the medium. On the standard designs the medium touches fluoropolymer only: the PFA lining and PFA or PTFE seats, plugs and bellows. The product pages list the exceptions, such as metal discs or filter elements offered on request.
Key properties of PFA resin
| Property | Typical value | Test method |
|---|---|---|
| Melting range | 302 – 315 °C | ASTM D3418 / resin data |
| Maximum continuous service temperature (resin, no load) | 260 °C | resin data |
| Tensile strength, 23 °C | 25 – 35 MPa | ASTM D638 |
| Elongation at break, 23 °C | 300 – 350 % | ASTM D638 |
| Flexural modulus | 0.54 – 0.64 GPa | ASTM D790 |
| Coefficient of linear expansion | approx. 12 × 10⁻⁵ /K | ASTM D696 |
| Water absorption | < 0.03 % | ASTM D570 |
| Oxygen index | > 95 % | ASTM D2863 |
| Volume resistivity | > 10¹⁷ Ω·cm | ASTM D257 |
| Water contact angle | approx. 115° | resin data |
| Critical surface tension | 17 – 18 mN/m | resin data |
Typical resin values from published resin and industry data. They are not guaranteed values for a finished valve.
Resin limit and valve limit are not the same. The resin is rated for continuous service to 260 °C. A lined valve is rated for the pressure and temperature combinations in its own P-T diagram, which depend on the lining, the seats and the body together. Our valves are rated up to +150 °C to +200 °C, depending on the line. Always use the product's P-T diagram, not the resin figure.
Chemical resistance — very broad, with known exceptions
PFA resists nearly all acids, bases and organic solvents across its service range. In published immersion tests the resin kept 81 – 100 % of its tensile strength after 7 to 28 days in, for example, concentrated hydrochloric acid at 100 °C, fuming nitric acid, a sulfuric acid / hydrogen peroxide mixture at 150 °C, toluene, xylene, aniline and phenol near their boiling points.
The exceptions are well documented:
-
molten alkali metals (for example sodium) and solutions of alkali metals;
-
elemental fluorine;
-
some complex halogenated compounds, such as chlorine trifluoride, at elevated temperature and pressure.
Some halogenated solvents (for example chloroform or carbon tetrachloride) are absorbed slightly and swell the polymer by a few percent without attacking it. Check the medium, concentration and temperature in our chemical resistance guide, or send them with your request.
Permeation
No plastic is a perfect barrier. Small molecules can diffuse slowly through a fluoropolymer wall without attacking it. Examples are hydrogen chloride, chlorine, bromine, hydrogen fluoride and some solvents. The rate rises with temperature and concentration and falls as the wall gets thicker. A dense, void-free lining is the main defence. If your medium permeates readily, tell us the temperature and duty cycle, and we will advise on the lining and body option.
The surface: low energy, smooth, low adhesion
PFA has one of the lowest surface energies of any solid. Its critical surface tension is about 17 – 18 mN/m and the water contact angle is about 115°, so water and most process liquids bead up and do not wet the surface. In practice:
-
Low adhesion of deposits. Crystals, polymers, pigments and biofilm precursors bond weakly to the surface and are more easily removed.
-
Cleanability. Cleaning-in-place cycles remove residues with less mechanical or chemical effort than wettable surfaces need.
-
Low flow resistance. The friction coefficient is low and the surface is non-wetting.
-
No surface treatment needed. PFA does not need passivation or derouging, because there is no metal oxide layer to maintain.
For clean-room and high-purity service, the Clean Room Series has electropolished 1.4408 (CF8M) bodies with virgin PFA linings. Custom-made options are a 1.4571 body, a high-purity PFA lining, a clean-room processed lining. Roughness values for the electropolished body exterior and for the lining surface are available on request.
No metal ions from the wetted surface — why it matters for pharma and semiconductor
PFA contains no metal in its molecular structure. A PFA-lined valve has no metal matrix in the wetted path that can corrode, passivate or release iron, chromium or nickel.
Stainless steel behaves differently. 316L relies on a chromium-rich passive film only a few nanometres thick. In hot high-purity water (water for injection) and in clean steam that film breaks down over time. Iron, chromium and nickel oxides and hydroxides form deposits known as rouge. They range from wipeable reddish-brown films to firmly adherent black magnetite in steam systems. ASME BPE covers rouge on stainless steel in a dedicated appendix, and the ISPE water and steam guide discusses monitoring, derouging and repassivation. Rouge particles can travel through the system and into the product.
Metal ions also matter on their own, before any visible rouge appears. Peer-reviewed studies of biologic formulations in contact with 316L show measurable leaching of iron, chromium and nickel, mostly in the ppb range. Leaching rises with chelating excipients, lower pH and longer contact, and proteins themselves can increase it. Metal ions can catalyse oxidation and aggregation of protein drugs. That is why metal leachables are part of extractables and leachables assessments.
In semiconductor wet processing the tolerances are tighter still. Roadmap targets for ultrapure water are in the parts-per-trillion range per critical metal. SEMI F57 sets the requirements semiconductor users apply to polymer components in ultrapure water and liquid chemical distribution: extractable ions, metals and organic carbon, and wetted-surface roughness.
A note of precision: "no metal ions" refers to the material. Any polymer can carry trace extractables from the resin and from processing. Where you need numbers for your qualification, ask us. We support your qualification with material data and resin documentation; inspection certificates to EN 10204 3.1 for the metal parts.
Food, pharma and biotech documentation
An FDA declaration for the PFA wetted parts is available on request. It is based on the resin manufacturer's declaration for the grade used (21 CFR 177.1550, perfluorocarbon resins). GMP compliance is a matter of the operator's practice. We supply the documents your quality system needs.
Other lining materials on request
Linings: virgin PFA (standard), PFA/AS (antistatic) and high-purity PFA. Other lining materials on request.
PFA/AS (antistatic)
PFA/AS — antistatic lining
Virgin PFA is an excellent electrical insulator, with a volume resistivity above 10¹⁷ Ω·cm. Usually that is an advantage. But liquids with low conductivity can build up electrostatic charge as they flow, and an insulating lining cannot lead that charge away. Flammable solvents are the typical case. Charge then collects on the lining surface and in the liquid, and it can discharge, inside or outside the valve. For these duties we offer PFA/AS, an antistatic (electrostatically dissipative) PFA lining.
What "antistatic" means — the classes in TRGS 727
The German technical rule TRGS 727 (avoiding ignition hazards from electrostatic charges) classifies materials by resistance. IEC TS 60079-32-1 gives the international guidance on the same scheme.
| Class | Surface resistance (23 °C, 50 % r.h.) | Volume resistivity |
|---|---|---|
| Conductive | ≤ 10⁴ Ω | ≤ 10⁴ Ω·m |
| Dissipative ("antistatic") | 10⁴ – 10⁹ Ω (up to 10¹¹ Ω at 30 % r.h.) | 10⁴ – 10⁹ Ω·m |
| Insulating | above the dissipative range | above the dissipative range |
TRGS 727 counts a conductive object as earthed when its leakage resistance to earth is ≤ 10⁶ Ω.
Our stated values for PFA/AS
| Value | PFA/AS |
|---|---|
| Surface resistance | < 10⁹ Ω |
| Leakage resistance to earth (via lining and body, valve earthed) | < 10⁶ Ω |
These values put PFA/AS in the dissipative class. That is why we call it antistatic, not conductive.
The valve must still be earthed
An antistatic lining only works if the charge has a path to earth. PFA/AS leads the charge into the metal body. From there it must reach earth through the piping. In practice:
-
earth the valve through the pipe flange bolting with toothed lock washers, or with a separate earthing cable where the bolting does not give a reliable path;
-
PFA/AS valves are supplied with an earthing connection between the internal metal parts and the body (on stem valves an earthing spring or contact washer); additional earthing equipment can be fitted on request;
-
check continuity after installation and after maintenance. Insulating gaskets, coatings and plastic piping sections can interrupt the path.
Non-conductive parts inside the valve, such as a virgin PTFE seat or packing, can limit the permitted hazardous zone or explosion group even with a PFA/AS lining. Some lines offer antistatic PTFE packing for this reason. Tell us the zone and the gas or vapour group with your request.
When to choose PFA/AS
Choose PFA/AS when one or more of these apply:
-
Low-conductivity, flammable liquids, such as many hydrocarbons and solvents. TRGS 727 calls liquids "low conductivity" at ≤ 50 pS/m (≤ 100 pS/m for non-hydrocarbons) and "medium" up to 10 000 pS/m.
-
Hazardous areas (ATEX zones) inside the valve or around it, for example during filling and emptying, when the valve is not completely full.
-
Two-phase flow: immiscible liquid droplets, suspended solids, gas bubbles or mist. Two-phase systems charge far more strongly than a clean single-phase liquid.
-
High flow velocities and strong turbulence: control valves, partly open valves, pump discharges.
-
Strainers and filters, which TRGS 727 treats as strong charge generators. This makes PFA/AS the natural choice for strainers in solvent service.
TRGS 727 also covers lined metal pipes directly. Insulating linings are acceptable only within limits on lining thickness, flow velocity and charge density, or with additional measures: keeping the line completely full, slowing to about 1 m/s during filling and emptying, and inerting. Otherwise the rule points to linings below 10⁸ Ω·m. Our valves carry no ATEX marking and there is no general approval. Chapter 3 of each operating manual lists the points the assessment must cover, including chargeable liquids with an insulating or an antistatic lining. Earthing and the hazardous-area assessment remain part of the plant operator's explosion-protection concept. We support it with the lining data and the valve documentation.
PTFE and PTFE-carbon
PTFE family — seats, bellows, baskets, packing
PTFE (polytetrafluoroethylene) has the same fully fluorinated chain as PFA and the same broad chemical resistance. Unlike PFA it does not melt into a flowing state, so PTFE parts are compression-moulded, sintered and machined. We use PTFE and its modified and filled grades where a part must slide, seal or flex: seats, plugs, bellows, packing, strainer baskets and seal rings.
| Property | PTFE | PFA (for comparison) |
|---|---|---|
| Melting point | 327 °C | 310 °C |
| Maximum continuous service temperature (no load) | 260 °C | 260 °C |
| Tensile strength, 23 °C | 20 – 35 MPa | 25 – 35 MPa |
| Elongation at break | 200 – 400 % | 300 – 350 % |
| Compressive strength (10 % deformation) | 10 – 15 MPa | 15 – 20 MPa |
| Dynamic friction coefficient | 0.1 | 0.2 |
| Coefficient of linear expansion | approx. 10 × 10⁻⁵ /K | approx. 12 × 10⁻⁵ /K |
Typical values from industry data. They are not guaranteed values for a finished part.
Why PTFE for seats, plugs and bellows
-
Lowest friction of the fluoropolymers. Ball and plug move with low torque and without lubricant in the wetted space.
-
Conformable. A PTFE seat deforms slightly to the ball or plug and seals tightly. Our control valves reach leakage class VI to ANSI/FCI 70-2 with PTFE-based seat and plug.
-
Chemically matched to the lining. Seat and lining resist the same media, so the seat does not become the weak point.
-
Flex life. PTFE and modified PTFE bellows tolerate many stroke cycles and seal the stem gas-tight without a dynamic packing in the medium.
The limit of virgin PTFE is creep ("cold flow"): under sustained load, and more so at higher temperature, it slowly deforms. Valve designs allow for this with confined seats, spring-loaded packing, and seat ratings that fall with temperature. That is one reason a valve's upper temperature limit is set by its seats, not by the resin's 260 °C.
Modified PTFE
Modified PTFE contains a small amount of a perfluorinated comonomer. That gives a denser structure with fewer voids. Compared with standard PTFE, published resin data show substantially lower deformation under load (roughly one third) and lower permeation (down to about half). Modified PTFE can also be welded. We use modified PTFE for control-valve seats and plugs and for sample-valve bellows.
PTFE-carbon and other filled grades
Fillers change the mechanical and electrical behaviour of PTFE:
-
Carbon and graphite reduce deformation under load and thermal expansion, raise thermal conductivity, and make the compound electrically dissipative or conductive. Carbon-filled PTFE grades are published with surface resistivity around 10⁴ Ω. We use PTFE-carbon composite for strainer baskets and seal rings and for antistatic packing.
-
Glass fibre raises strength and wear resistance. It is not used in hydrofluoric acid or strong alkalis, which attack the glass.
Fillers also bring limits. Carbon-filled grades are not used in strongly oxidising media, such as hot concentrated nitric or sulfuric acid or chromic acid. Glass-filled grades are not used in hydrofluoric acid or hot alkalis. For these media, virgin or modified PTFE is the right choice. We select the grade for your medium.
Body and trim metals
Body and trim metals
In a lined valve the metal does the structural work: it carries pressure, pipe loads and bolting. The PFA lining keeps the medium away from it. The body material is therefore chosen for strength at the operating temperature, toughness at the lowest temperature, the external environment, and the documentation your plant requires. It is not chosen for resistance to the medium. All body materials are supplied with EN 10204 3.1 certificates.
| Material | Standard | Equivalent (approx.) | Type | Where we use it |
|---|---|---|---|---|
| 1.0619 — GP240GH | EN 10213 | ASTM A216 WCB | Cast carbon steel for pressure purposes | Standard body on all lines |
| 1.4408 — GX5CrNiMo19-11-2 | EN 10213 | ASTM A351 CF8M | Austenitic stainless casting with molybdenum | Body option on all lines; low-temperature option; Clean Room Series (electropolished) |
| 1.4409 — GX2CrNiMo19-11-2 | EN 10213 | ASTM A351 CF3M | Low-carbon version of 1.4408 | Body option on all lines, same P-T diagram (ball valve: on request) |
| 1.4571 — X6CrNiMoTi17-12-2 | EN 10088 | AISI 316Ti | Wrought stainless, Ti-stabilised | Custom option, Clean Room Series |
| 1.4301 — X5CrNi18-10 | EN 10088 | AISI 304 | Wrought stainless | Small parts, e.g. earthing spring and locking washer (ball valve) |
| CD4MCuN | ASTM A890 / A995 Grade 1B | ≈ 1.4517 (GX2CrNiMoCuN25-6-3-3) | Duplex (ferritic-austenitic) stainless casting | Core of the one-piece PFA-lined ball-stem (ball valve) |
| A2 / A4 bolting | EN ISO 3506 | 304 / 316 class | Stainless fasteners | Studs, nuts, washers |
- P265NH — pressure-equipment steel for machined and fabricated pressure parts such as flanges and plates.
(Paul 24.10.: no ductile iron / old designations such as "GGG40.3" — list only materials we actually use.)
When to choose which body
-
1.0619 / WCB is the economical standard for indoor and covered plant at normal and moderately low temperatures, with a painted exterior.
-
1.4408 / 1.4409 stainless where the outside of the valve needs corrosion resistance: corrosive atmospheres, washdown, outdoor coastal sites. Also clean rooms, where an electropolished stainless exterior is easy to keep clean. 1.4408 (with molybdenum) is preferred in chloride-laden atmospheres.
-
1.4408 for low temperatures. Austenitic stainless steels keep their toughness at low temperatures. On our lines the 1.4408 body extends the lower limit to −60 °C where the line's P-T diagram shows it.
-
1.4409 / 1.4571 when your specification calls for a low-carbon or stabilised grade.
Low-temperature notes (no pressure values here — see each product's P-T diagram)
-
1.0619: standard lower limit −10 °C. Below that, the pressure-equipment rules (PED Annex I via AD 2000-Merkblatt W 10) allow use down to −60 °C only at reduced allowable pressure. That is the 12-bar block below −10 °C shown on some of our PN 16 diagrams.
-
ASTM A216 WCB: ASME B16.34 lists −29 °C as its lower limit. Lower temperatures call for impact-tested low-temperature grades.
-
1.4408 / 1.4409: rated on our lines to −60 °C. Lower on request.
-
The lower limit of the valve is set by the body, the stem or ball core and the bolting together. We state it per line.
Special alloys and ceramics
Special alloys and ceramics — where metal or ceramic meets the medium
Some parts cannot be lined, or must be harder than any plastic: discs and filter elements on request, ceramic balls, pump shafts and bearings. For these we work with corrosion-resistant alloys and technical ceramics. Each has its own limits. None resists every medium.
Nickel-chromium-molybdenum alloys
| Alloy (generic name) | Material no. | UNS | Character |
|---|---|---|---|
| Alloy C-276 | 2.4819 (NiMo16Cr15W) | N10276 | Very good in both reducing and oxidising media; strong resistance to pitting, crevice corrosion and chloride stress-corrosion cracking |
| Alloy 22 | 2.4602 (NiCr21Mo14W) | N06022 | More chromium and less molybdenum than C-276, so better in strongly oxidising media |
We use these alloys for wetted metal parts on request, such as butterfly-valve discs and strainer elements above +150 °C, and for custom parts.
Titanium
Titanium (for example Grade 2, 3.7035) forms a stable oxide film. It performs very well in wet chlorine, seawater and many oxidising chloride solutions. It must not be used in hydrofluoric acid or fluoride-bearing media, or in dry chlorine. We offer titanium discs on request for the butterfly valve.
Technical ceramics
| Ceramic | Typical properties | Use at GFT9 |
|---|---|---|
| SSiC — sintered silicon carbide | Density about 3.1 g/cm³; very hard (Vickers HV10 ≥ 22 GPa); high thermal conductivity (about 100 – 200 W/m·K); resistant to nearly all acids and alkalis | Ball (ball valve DN 15 / DN 20, two-piece ball-stem); pump shafts, bearings and bushes |
| Al₂O₃ — high-purity alumina | Hard, wear-resistant, electrically insulating; chemical resistance depends on purity and grain-boundary phase | Ball (ball valve DN 15 / DN 20, two-piece ball-stem) |
Sintered SiC contains almost no free silicon, so it is preferred over silicon-infiltrated SiC (SiSiC) where hydrofluoric acid or strong hot alkalis are present. Alumina with a glassy grain-boundary phase can be attacked by hydrofluoric acid. Tell us the medium, and we choose the grade.
Pump spare parts
We make spare parts for sealless magnetic-drive pumps: lined impellers, SSiC shafts, bearings and bushes, and containment shells. We work from the worn part: we measure it, document the geometry and materials, and keep the record on file as the basis for your equivalence approval later.
Material notes for the parts:
-
Shafts and bearings run in the pumped liquid as their only lubricant. SSiC combines hardness, wear resistance and chemical resistance with high thermal conductivity, which helps against heat build-up during brief dry running.
-
Containment shells separate the medium from the drive magnets. A metallic shell carries eddy currents that turn drive power into heat; in large pumps the loss can reach 15 – 25 % of the total power. Non-metallic shells avoid most or all of this: fibre-reinforced composites reduce the loss, ceramics eliminate it. We advise on the material for your pump and medium.
-
Impellers are PFA-lined and finished in house.
We support your qualification of a replacement part with measurement records, material certificates and first-article documentation. The approval itself stays with you.
Which material when
Which material when
A starting point. The final choice depends on the medium, concentration, temperature, pressure and installation. Send us these with your request.
| Duty / medium | Lining | Seat, plug, packing | Body | Notes |
|---|---|---|---|---|
| Mineral acids, alkalis, oxidisers, most solvents — general chemical service | Virgin PFA | PTFE / modified PTFE | 1.0619 (WCB) | Check exceptions (alkali metals, fluorine, ClF₃) |
| Flammable, low-conductivity liquids; hazardous areas; two-phase flow; high velocities; strainers in solvent service | PFA/AS (antistatic) | Antistatic packing where available | 1.0619 or stainless | Valve must be earthed; tell us the zone and group |
| Readily permeating media (HCl, Cl₂, Br₂, HF) at elevated temperature | Virgin PFA | PTFE / modified PTFE | per environment | Tell us the temperature and duty cycle |
| Water for injection, clean steam condensate, biopharma, food | Virgin PFA | PTFE / modified PTFE | 1.4408 (CF8M), electropolished — Clean Room Series | No metal in the wetted path; FDA declaration on request |
| Semiconductor wet chemicals, ultrapure water | Virgin PFA; high-purity PFA as a custom option | PTFE / modified PTFE | 1.4408, electropolished | Qualification data on request |
| Low temperatures, −10 °C to −60 °C | per medium | per medium | 1.4408 (CF8M) | Per the line's P-T diagram |
| Corrosive atmosphere, washdown, coastal or outdoor sites | per medium | per medium | 1.4408 / 1.4409 | External corrosion governs the body |
| Wetted metal part needed (disc, filter element above +150 °C) | — | — | — | Alloy C-276, alloy 22 or titanium, chosen for the medium |
| Hard, wear-resistant ball (DN 15 / DN 20) | — | — | — | SSiC or Al₂O₃ ball on request |
| Magnetic-drive pump spares | Lined impellers | — | — | SSiC shafts and bearings; containment shell material per pump and medium |
FAQ
Is PFA resistant to all chemicals? No material is. PFA resists nearly all acids, bases and solvents. The known exceptions are molten alkali metals, elemental fluorine and some halogen compounds such as chlorine trifluoride at elevated temperature and pressure. Some media also permeate slowly at high temperature. Check your medium in our chemical resistance guide or ask us.
PFA or PFA/AS — which do I need? PFA is the standard. Choose PFA/AS (antistatic) for flammable liquids with low conductivity, in hazardous areas, with two-phase flow or high flow velocities, and for strainers in solvent service. PFA/AS has a surface resistance below 10⁹ Ω, which is the dissipative class in TRGS 727. The valve must be earthed.
Does a PFA/AS valve still need earthing? Yes. The antistatic lining leads charge into the body, and the body must lead it to earth: through flange bolting with toothed lock washers or a separate earthing cable. Check continuity after installation and after maintenance.
Why a PFA-lined valve instead of 316L stainless steel in high-purity service? Stainless steel relies on a thin passive film. In hot purified water and clean steam it can form rouge and release iron, chromium and nickel. PFA has no metal in the wetted path, needs no passivation or derouging, and its low-energy surface resists deposits. We support your qualification with material data and certificates.
Is your PFA FDA approved? FDA does not approve materials or valves in that sense. We supply an FDA declaration for the PFA wetted parts on request, based on the resin supplier's declaration under 21 CFR 177.1550.
Can you supply alloy C-276, titanium or ceramic parts? Yes, on request. Examples are butterfly-valve discs, strainer elements for higher temperatures, SSiC or alumina balls in small ball valves, and SSiC shafts and bearings for magnetic-drive pumps. Send us the medium and temperature, and we propose the material.
Ask about your medium