Chemical tank farm with bunded storage tanks, pipe bridges and access stairways on an overcast day

Chemical Storage & Tank Farms

PFA-Lined Valves for Chemical Storage, Tank Farms and Transfer

The first valve under the tank decides how safely a tank farm runs

In a tank farm, most corrosion damage happens at a few points: the outlet nozzle, the first valve below the tank, the sampling point and the loading connection. These are the points that see dilution, sediment, washing water and every change of flow.

GFT9 supplies PFA-lined valves for exactly these points — ball valves, check valves, strainers, sight glasses and sample valves from our standard ranges — and designs tank outlet, drain and sampling valves to your tank connection when a catalogue valve does not fit.

We also line tank valves for other valve makers. The same capability is available to you directly.

Discuss Your Tank Equipment →

Why PFA

Why Lined Valves at the Tank

One lining for many media. A tank farm stores acids, caustics and hypochlorite side by side. PFA lining resists the media in the table below with one lining material; check your medium and temperature with us.

Dead space is a corrosion pocket. Product that stands in a nozzle or valve cavity concentrates, crystallises or picks up moisture. Tank outlets work best with the valve seat as close to the tank as the design allows — which is why we build outlets to the actual tank connection.

Washing and dilution. Tanks, lines and hoses are washed and flushed. For acids such as sulfuric acid, dilution is what destroys carbon steel — see our page on sulfuric acid storage and terminals. A PFA lining resists the diluted acid.

Sampling without exposure. Closed sampling takes a representative sample from the flowing product instead of a stagnant dead leg, and keeps operators away from the medium.

Transport tanks are different. Valves on rail and road tank cars are part of an approved tank design under ADR/RID and are not chosen freely. For tank and valve makers in this market we line components to their design.

Applications

Applications in Storage and Transfer

Tank outlets and drains

First isolation below the tank, drain and flushing connections — standard ball valves or custom outlet valves built to your nozzle.

→ Spheron9 ball valve, DN 15 – 200 · up to 16 bar · up to +200 °C · Custom outlet valves to your nozzle

Tank and line sampling

Closed sampling of stored product and of transfer lines for quality control and release.

→ Provaron9 sample valve, DN 25 – 80 · up to 16 bar · up to +150 °C

Transfer, pumps and loading

Isolation, backflow protection and strainers on pump suction and discharge, and at loading arms and hose connections.

→ Papilon9 butterfly valve, DN 40 – 600 · 10 bar to DN 450, 6 bar DN 500 – 600 · up to +200 °C · Vibron9 swing check valve, DN 40 – 400 · up to 16 bar · up to +150 °C · Prohibron9 ball check valve, DN 15 – 200 · up to 10 bar · up to +200 °C · Purion9 T-strainer, DN 25 – 150 · PN 16 · −10 °C up to +150 °C

Visual control

Sight glasses on filling and loading lines to confirm flow and product condition.

→ Videron9 sight glass, DN 15 – 250 · 16 bar · up to +150 °C

Lining for OEM tank and valve makers

Lining of tank valves, nozzles and components to the maker's drawing, from single pieces to series.

Chemical resistance

Typical media and PFA resistance

MediumFormulaConcentrationMax. temp.Rating
Sulfuric AcidH₂SO₄Up to 98 %per valve P-T rating Excellent
Hydrochloric AcidHClUp to 37 %120 °C Excellent
Nitric AcidHNO₃Up to 70 %80 °C Excellent
Phosphoric AcidH₃PO₄Up to 85 %120 °C Excellent
Sodium HydroxideNaOHUp to 50 %120 °C Excellent
Sodium HypochloriteNaOClUp to 15 %60 °C Excellent

PFA lining resists the acids, alkalis and oxidisers listed above — see the full resistance guide. Hot strong-acid circulation in drying and absorption towers is not covered by this table. Temperature limits shown are conservative for continuous service; the valve's own limit is its P-T rating. Contact us for your media and conditions.

Excellent full resistance, continuous service · Good suitable for most applications · Limited check the conditions with us. Ratings refer to the PFA lining; the valve's own pressure–temperature rating also applies.

Products

PFA-Lined Products for Tanks and Tank Farms

Tank Outlet, Drain and Sampling Valves — Custom-Made

Tank Outlet, Drain and Sampling Valves — Custom-Made

Designed to your tank connection and lined in PFA — from a drawing, a sketch or an existing valve. Carbon steel, stainless steel or other alloys outside; single pieces to series.

Discuss a Tank Valve →
PFA-Lined Ball Valves — Spheron9

PFA-Lined Ball Valves — Spheron9

Full-bore isolation at tank outlets, on transfer lines and at loading connections.

DN 15 – DN 200 / NPS ½" – 8" · up to 16 bar · up to +200 °C, see P-T diagram · TA-Luft leakage class BH (DN 10 – DN 150, certified −20 °C to +180 °C) · actuator mounting to EN ISO 5211.

View Ball Valve Range →
PFA-Lined Sample Valves — Provaron9

PFA-Lined Sample Valves — Provaron9

Sampling from lined lines without opening the system. DN 25 – DN 80 / NPS 1" – 4" · up to 16 bar · −10 °C up to +150 °C.

View Sample Valve Range →
PFA-Lined Check Valves and Sight Glasses

PFA-Lined Check Valves and Sight Glasses

Vibron9 swing check valves, DN 40 – DN 400 / NPS 1½" – 16" · up to 16 bar · −40 °C up to +150 °C, on pump discharges. Videron9 sight glasses, DN 15 – DN 250 / NPS ½" – 10" · 16 bar · −10 °C up to +150 °C, on filling and loading lines.

View Swing Check Valve Range →

Quality

Quality and Documentation

  • Every valve is pressure-tested before delivery to DIN EN 12266-1.
  • EN 10204 3.1 material certificates with heat numbers.
  • Pressure-bearing products designed and manufactured to PED 2014/68/EU; the Spheron9 ball valve additionally certified under Module A2 with notified body 0035 and type-tested to TA-Luft (leakage class BH, DN 10 – DN 150, certified −20 °C to +180 °C).
  • Made in Germany · country of origin Germany.

FAQ

Questions we are often asked

Can GFT9 build a tank outlet valve to our nozzle?

Yes — tank outlet, drain and sampling valves are designed to your tank connection from a drawing, a sketch or an existing valve, and lined in PFA, from single pieces to series. Valves on rail and road tank cars are part of an approved tank design and are supplied to the tank or valve maker's specification.

PFA or PTFE lining — what is the difference?

Both are fully fluorinated plastics with almost universal chemical resistance. PTFE cannot be melted, so PTFE liners are pressed and sintered. PFA can be melted, so we transfer-mould it into the valve body: the lining is dense, anchored in the body and follows complex shapes. If your specification says "PTFE-lined", a PFA-lined valve meets the same chemical duty — ask us for a comparison for your medium.

Which documents come with the valves?

Every valve is tested to DIN EN 12266-1 and ships with EN 10204 3.1 material certificates. Pressure-bearing products are designed and manufactured to PED 2014/68/EU; the Spheron9 ball valve is additionally certified under Module A2 and type-tested to TA-Luft.

Which PFA-lined valve goes where in a tank farm?

Tank outlets, drains and transfer lines: Spheron9 ball valve, DN 15 – 200, up to 16 bar. Large headers: Papilon9 butterfly valve, DN 40 – 600, 10 bar to DN 450 and 6 bar DN 500 – 600. Pump discharges: Vibron9 swing check valve, DN 40 – 400, or Prohibron9 ball check valve, DN 15 – 200. Sampling: Provaron9 sample valve, DN 25 – 80. Filling and loading lines: Videron9 sight glass, DN 15 – 250. Where a catalogue valve does not fit the tank nozzle, we design the outlet valve to your connection.

Discuss Your Tank Equipment

Send us the medium, tank connection (size, standard, drawing or photo), pressure, temperature and quantity. For custom outlets, sampling valves and lined T-pieces or spools up to DN 350 we start from your nozzle or drawing.

We work with tank-farm and terminal operators, tank and valve manufacturers, and maintenance contractors.

Email: sales@gft9.shop Phone: +49 2152 9148591

Related: Sulfuric acid terminals · Hypochlorite and water treatment · Chemical processing

Request Quotation →

Contact form