PFA-Lined Ball Valve Spheron9

Shut-off · PFA-lined ball valve

PFA-Lined Ball Valve Spheron9

Full bore · 2-way · flanged · DN 15 – 200 / NPS ½" – 8" · PN 16 / Class 150 · for corrosive and high-purity media

Sizes
DN 15 – 200 · NPS ½" – 8"
Pressure
PN 16 / Class 150 · up to 16 bar
Temperature
−60 °C … +200 °C by body material
Certified
PED Module A2 · TA-Luft BH

Full-bore ball valve with PFA-lined body and end flange and a one-piece PFA-lined ball-stem — for transfer and loading lines, tank outlets, dosing-line isolation and automated on/off duty. One page for both norms: choose the size (EN or ASME), lining and operation, and send the configuration as a request for quotation.

Configure & request a quote

Features

PFA-lined throughout

Body, end flange and ball are lined; the medium touches fluoropolymer only.

One-piece PFA-lined ball-stem

As standard. Two-piece only for SSiC or Al₂O₃ ceramic balls (DN 15/20).

Two-stage blow-out protection

On all sizes — bottom-entry stem plus retaining washer.

Spring-loaded stem seal

Compensates packing set and thermal relaxation; no scheduled readjustment in normal service.

TA-Luft leakage class BH

To DIN EN ISO 15848-1, DN 10 – 150, certified −20 °C to +180 °C.

PED 2014/68/EU, Module A2

Notified body 0035. CE marking from DN 25 / 1".

Actuator-ready

Mounting to EN ISO 5211; bracket and coupling made to suit the actuator flange.

100 % tested

To DIN EN 12266-1, with EN 10204 3.1 certificates.

Which version for which duty

DutyChoose
Isolation in transfer and loading lines, tank outletsSpheron9 with lever or handwheel
Automated on/off dutyElectric or pneumatic actuator; EN ISO 5211 mounting
Media where electrostatic charge must be led offPFA/AS (conductive) lining
Low temperatures down to −60 °CBody 1.4408 (CF-8M)
Clean rooms, pharma, semiconductorSpheron9 Clean Room — electropolished 1.4408 body
Throttling or regulationV-control ball on request — or the Imperium9 control valve

Configure and request a quote

Your configuration

Reference: SPH9-DN015-PFA-LEV

No order and no payment — we answer with a quotation. Your data is used only to answer this request (privacy policy).

Technical data

TypeBall valve, full bore, 2-way, on/off service; lever operated or actuated
SizesDN 15 – 200 · NPS ½" – 8"
Pressure ratingPN 16 / Class 150 — up to 16 bar, see P-T diagram
Temperature−10 °C (1.0619) or −60 °C (1.4408 / 1.4409) up to +200 °C — see P-T diagram. TA-Luft certification valid −20 °C to +180 °C
FlangesEN 1092-1 (PN 16, form B1) · ASME B16.5 (Class 150, RF)
Face-to-faceEN 558 Series 1 (PN) · ASME B16.10 (Class)
Body1.0619 (A216 WCB) or 1.4408 (CF-8M); 1.4409 on request
LiningPFA, PFA/AS (conductive) — FEP, PFA/UP, PVDF, UHMW-PE on request
ActuationEN ISO 5211 — bracket and coupling made to suit the actuator flange
OptionsActuation, stem extension, heating jacket, lock; V-control ball on request
Testing100 % per valve to DIN EN 12266: shell 24 bar, shell and seat tightness 6 bar; EN 10204/3.1. 15 kV spark test on request
CertificatesPED 2014/68/EU Module A2, NB 0035 · TA-Luft (8/2021) §5.2.6.4 / DIN EN ISO 15848-1: ISO FE–BH–C03–SSA1–t(−20/+180 °C)–PN16, DN 10 – 150 / ½" – 6"
Origin and qualityMade in Germany · country of origin Germany · ISO 9001:2015 certified manufacturing

Materials

Exploded view — positions as in the materials table
Exploded view — positions as in the materials table
Pos.PartMaterial
1, 2, 10Body / End Flange / Gland Follower1.0619 (A216 WCB), 1.4408 (CF-8M)
1, 2, 6Lining Body / BallPFA, FEP, PFA/AS, PFA/UP, PVDF, UHMW-PE*
6Ball / StemCD4MCuN
7Lever1.0619 (A216 WCB), 1.4408 (CF-8M)
4Seat RingsPTFE/TFM, PTFE/AS, GF PTFE, o. o. req.
3Stem packingPTFE/TFM, PTFE/AS
8Spring Gland FollowerSpring Steel
5Thrust RingSteel
11Earthing Spring1.4301
12Retaining Washer1.4301
9, 13–19Bolts, Nuts and WashersStainless Steel A2, A4, 5.6, o. o. req.

Wetted parts: lining and ball (PFA or the selected lining material) and seat rings. Further lining materials on request.

Pressure–temperature rating

Pressure-Temperature diagram for GFT9 PFA-lined ball valves up to DN 150, non-vacuum service. DN 200 pressure-temperature data on request.

Pressure-Temperature diagram for GFT9 PFA-lined ball valves up to DN 150, non-vacuum service. DN 200 pressure-temperature data on request. Lower limit set by the body casting: 1.0619 −10 °C, A216 WCB −29 °C, 1.4408 −60 °C.

Dimensions

General arrangement — symbols as in the tables below
General arrangement — symbols as in the tables below

EN version — EN 1092-1 PN 16, EN 558 Series 1 · mm

SizeL1H1ØDØkØdn × ØBKv m³/h*Torque 16 bar Nm**Max. adm. Nm
DN 151301269565454 x 14 (M12)17.51080
DN 2015012610575584 x 14 (M12)311080
DN 2516012611585684 x 14 (M12)751280
DN 32180126140100784 x 18 (M16)140on req.on req.
DN 40200200150110884 x 18 (M16)20025250
DN 502302001651251024 x 18 (M16)31030250
DN 652902201851451224 x 18 (M16)615on req.on req.
DN 803102602001601388 x 18 (M16)80080500
DN 1003502702201801588 x 18 (M16)1250170500
DN 125400—2502101888 x 18 (M16)2100on req.on req.
DN 150480—2852402128 x 22 (M20)2800on req.on req.
DN 200600—34029526812 x 22 (M20)6000on req.on req.

ASME version — ASME B16.5 Class 150 RF, ASME B16.10 · mm

SizeL1H1ØDØkØdn × ØBKv m³/h*Torque 16 bar Nm**Max. adm. Nm
NPS ½"10812688.960.334.94 x 15.917.51080
NPS ¾"11712698.469.842.94 x 15.9311080
NPS 1"12720010879.450.84 x 15.9751280
NPS 1½"16520012798.4734 x 15.920030250
NPS 2"178200152.412192.14 x 1931030250
NPS 3"203260190.5152.41274 x 1980080500
NPS 4"229270228.6190157.28 x 191250170500
NPS 6"394—2792412168 x 22.22800on req.on req.
NPS 8"457—342.9298.5269.98 x 22.26000on req.on req.

* Kv indicative, full bore; Cv ≈ 1.156 × Kv. ** Operating torque greased, guide value — size actuators with the usual safety margin; "on req." sizes are confirmed per order. Dimensions nominal — confirm against the certified drawing before piping design. The row of your selected size is highlighted; sizes without a row: dimensions on request.

Documents

Used in

Chemical processingSulfuric acid terminalsChemical storage & tank farmsMining & hydrometallurgyWater treatmentEnergyPharmaceutical & biopharmaSemiconductor

FAQ

Questions we are often asked

Which operation should I choose?

Lever for manual isolation; lever + lock where the valve must not be operated by mistake; handwheel for larger sizes. Electric or pneumatic actuators (with positioner or limit switches) for automated duty. Choose “Bridge for actuator mounting” if you fit your own actuator — mounting to EN ISO 5211.

PFA or PFA/AS lining?

PFA is the standard lining. PFA/AS is the conductive version for media where electrostatic charge must be led off. FEP, PFA/UP, PVDF and UHMW-PE are available on request.

Can the Spheron9 throttle?

It is an on/off valve. A V-control ball is available on request with a longer lead time; for regulation use the Imperium9 control valve.

Which documents come with each valve?

Every valve is tested to DIN EN 12266-1 and ships with EN 10204 3.1 material certificates. The Spheron9 is certified under PED 2014/68/EU Module A2 (CE marking from DN 25 / 1") and type-tested to TA-Luft leakage class BH (DN 10 – 150).

PFA or PTFE lining — what is the difference?

Both are fully fluorinated plastics with almost universal chemical resistance. PTFE cannot be melted, so PTFE liners are pressed and sintered. PFA can be melted, so we transfer-mould it into the valve body: the lining is dense, anchored in the body and follows complex shapes. If your specification says "PTFE-lined", a PFA-lined valve meets the same chemical duty — ask us for a comparison for your medium.

Related