PFA-Lined Sample Valve Provaron9

Sampling · PFA-lined sample valve

PFA-Lined Sample Valve Provaron9

Gas-tight bellows seal · flanged · DN 25 – 80 / NPS 1" – 3" · PN 16 / Class 150 · for corrosive, toxic and high-purity media

Sizes
DN 25 – 80 · NPS 1" – 3"
Pressure
Vacuum up to 16 bar
Temperature
−10 °C … +150 °C
Stem seal
Gas-tight PTFE bellows

Sample valve with PFA-lined body and a gas-tight PTFE bellows seal — for taking samples from lined lines without opening the system, at transfer and loading lines, tank outlets and reactor sampling points. One page for both norms: choose the size (EN or ASME) and the lining, and send the configuration as a request for quotation.

Configure & request a quote

Features

PFA-lined sample path

Body and sample path are lined with virgin PFA, like the line the valve sits in.

Gas-tight PTFE bellows seal

Hermetically sealed stem; gas-tight to DIN EN 12266-1, leakage rate A.

Suitable for vacuum service

PFA lining anchored in dovetail grooves in the body — suitable for vacuum service; limits per P-T diagram or on request.

Top-entry design

Maintenance is possible without removing the valve from the line.

Adjustable stroke limitation

Finely dosed sampling, also with closing-force amplification during sampling.

Bottle connection

GL connection for standard bottle DIN 168 with vent connection, or a customised connection to suit your system.

Vertical or horizontal installation

For installation in all environments with compatible sampling bottle adapters.

Security options

Stainless steel safety box against leakage from the bottle; padlock option prevents accidental operation.

Which version for which duty

DutyChoose
Quality control on transfer, loading and process linesProvaron9 in the line size DN 25 – 80 / NPS 1" – 3"
Tank and reactor sampling pointsProvaron9 with GL bottle connection
Toxic or aggressive media; operator protectionGas-tight bellows seal; optional safety box and padlock
Media where electrostatic charge must be led offPFA/AS (antistatic) lining
Pharma and high-purity dutyProvaron9 Clean Room — electropolished 1.4408 body
Bottle connection other than GL / DIN 168Customised bottle connection on request

Configure and request a quote

Your configuration

Reference: PRV9-DN025-PFA

No order and no payment — we answer with a quotation. Your data is used only to answer this request (privacy policy).

Technical data

TypeSample valve, flanged, top-entry; PTFE bellows stem seal; automatic reset closure
SizesDN 25 – 80 · NPS 1" – 3"
Pressure ratingPN 16 / Class 150 — vacuum up to 16 bar, see P-T diagram
VacuumPFA lining anchored in dovetail grooves in the body — suitable for vacuum service; limits per P-T diagram or on request.
Temperature−10 °C up to +150 °C; lower and higher temperatures on request — see P-T diagram
FlangesEN 1092-1 (PN 16) · ASME B16.5 (Class 150, RF)
Face-to-faceEN 558-1 Series 1
Body1.0619 (A216 WCB) or 1.4408 (CF8M); clean room version 1.4408 (CF8M) electropolished
LiningPFA, PFA/AS (antistatic) — PFA/UP, PVDF, PP, UHMW-PE on request
Stem sealGas-tight PTFE bellows; DIN EN 12266-1 leakage rate A
Bottle connectionGL connection for standard bottle DIN 168 with vent; customised connection on request
OptionsPadlock; stainless steel safety box; customised bottle connection
TestingEvery valve pressure-tested in Germany before shipment. Pressure test to DIN EN 12266-1: body 24 bar, spark test on request; EN 10204 3.1 material certificates
DirectiveDesigned and manufactured to PED 2014/68/EU
Origin and qualityMade in Germany · country of origin Germany · ISO 9001:2015 certified manufacturing

Materials

Pos.PartMaterial
100Body1.0619 (A216 WCB)/PFA*
106CoverStainless Steel
203LeverStainless Steel
205Valve Seat1.0619 (A216 WCB)
206BellowsPTFE
226Flange ConnectionModified PTFE
302Guide RingPTFE-Carbon
400O-RingFKM
402Packing RingPTFE
509Stuffing BoxStainless Steel
514NutHDPE
904Spring CapStainless Steel
920Spring BushingStainless Steel
952Threaded PinStainless Steel
954NutStainless Steel
956Compression SpringStainless Steel

Wetted parts: lining (PFA or the selected lining material), modified PTFE bellows and adapter. Further lining materials on request.

Pressure–temperature rating

Operating Pressures and Temperatures for the PFA lined Sample Valve

Operating Pressures and Temperatures for the PFA lined Sample Valve Up to 16 bar. Lower and higher temperatures than −10 °C … +150 °C on request.

Dimensions

Section — dimension letters as in the tables below
Section — dimension letters as in the tables below

EN version — EN 1092-1 PN 16, EN 558 Series 1 · mm

SizeLHH1ØDØkØdn × ØBKvs m³/h (EN) / Cv (ASME)*Sampling cone — conical / flat*
DN 2516019012311585684 x 14 (M12)15conical 0.385 / flat 2.56
DN 40200250127150110884 x 18 (M16)47conical 0.385 / flat 2.56
DN 502301951311651251024 x 18 (M16)65conical 0.385 / flat 2.56
DN 803103101732001601388 x 18 (M16)200conical 0.385 / flat 2.56

ASME version — ASME B16.5 Class 150 RF, ASME B16.10 · mm

SizeLHH1ØDØkØdn × ØBKvs m³/h (EN) / Cv (ASME)*Sampling cone — conical / flat*
NPS 1"16019012310879.450.84 x 15.917.5conical 0.448 / flat 2.98
NPS 1½"20025012712798.4734 x 15.954.8conical 0.448 / flat 2.98
NPS 2"165195131152.412192.14 x 1975.7conical 0.448 / flat 2.98
NPS 3"200310173190.5152.41274 x 19233conical 0.448 / flat 2.98

* Valve Kvs in m³/h (EN rows) or Cv (ASME rows), indicative; sampling-cone values in the same unit as the row. Dimensions nominal — confirm against the certified drawing before piping design. The row of your selected size is highlighted; sizes without a row: dimensions on request.

Documents

Used in

Chemical processingFine chemicals & APIPharmaceutical & biopharmaFood & beverageChemical storage & tank farmsSulfuric acid terminals

FAQ

Questions we are often asked

PFA or PFA/AS lining?

PFA is the standard lining (virgin PFA). PFA/AS (antistatic) is for media where electrostatic charge must be led off. PFA/UP, PVDF, PP and UHMW-PE are available on request.

Which bottle connection is fitted?

A GL connection for a standard bottle to DIN 168, with vent connection. A customised bottle connection can be made to suit your existing system.

Can it be installed vertically or horizontally?

Yes, in both positions, with compatible sampling bottle adapters. The valve is top-entry, so maintenance is possible without removing it from the line.

Is the Provaron9 suitable for vacuum service?

PFA lining anchored in dovetail grooves in the body — suitable for vacuum service; limits per P-T diagram or on request.

Which documents come with each valve?

The valve is pressure-tested to DIN EN 12266-1 (leakage rate A, gas-tight) and EN 10204 3.1 material certificates are available. It is designed and manufactured to PED 2014/68/EU.

PFA or PTFE lining — what is the difference?

Both are fully fluorinated plastics with almost universal chemical resistance. PTFE cannot be melted, so PTFE liners are pressed and sintered. PFA can be melted, so we transfer-mould it into the valve body: the lining is dense, anchored in the body and follows complex shapes. If your specification says "PTFE-lined", a PFA-lined valve meets the same chemical duty — ask us for a comparison for your medium.

Related

Provaron9 Clean RoomVideron9 sight glassSpheron9 ball valveChemical resistance guide