Sampling · PFA-lined sample valve
PFA-Lined Sample Valve Provaron9
Gas-tight bellows seal · flanged · DN 25 – 80 / NPS 1" – 3" · PN 16 / Class 150 · for corrosive, toxic and high-purity media
- Sizes
- DN 25 – 80 · NPS 1" – 3"
- Pressure
- Vacuum up to 16 bar
- Temperature
- −10 °C … +150 °C
- Stem seal
- Gas-tight PTFE bellows
Sample valve with PFA-lined body and a gas-tight PTFE bellows seal — for taking samples from lined lines without opening the system, at transfer and loading lines, tank outlets and reactor sampling points. One page for both norms: choose the size (EN or ASME) and the lining, and send the configuration as a request for quotation.
Features
PFA-lined sample path
Body and sample path are lined with virgin PFA, like the line the valve sits in.
Gas-tight PTFE bellows seal
Hermetically sealed stem; gas-tight to DIN EN 12266-1, leakage rate A.
Suitable for vacuum service
PFA lining anchored in dovetail grooves in the body — suitable for vacuum service; limits per P-T diagram or on request.
Top-entry design
Maintenance is possible without removing the valve from the line.
Adjustable stroke limitation
Finely dosed sampling, also with closing-force amplification during sampling.
Bottle connection
GL connection for standard bottle DIN 168 with vent connection, or a customised connection to suit your system.
Vertical or horizontal installation
For installation in all environments with compatible sampling bottle adapters.
Security options
Stainless steel safety box against leakage from the bottle; padlock option prevents accidental operation.
Which version for which duty
| Duty | Choose |
|---|---|
| Quality control on transfer, loading and process lines | Provaron9 in the line size DN 25 – 80 / NPS 1" – 3" |
| Tank and reactor sampling points | Provaron9 with GL bottle connection |
| Toxic or aggressive media; operator protection | Gas-tight bellows seal; optional safety box and padlock |
| Media where electrostatic charge must be led off | PFA/AS (antistatic) lining |
| Pharma and high-purity duty | Provaron9 Clean Room — electropolished 1.4408 body |
| Bottle connection other than GL / DIN 168 | Customised bottle connection on request |
Configure and request a quote
Your configuration
Reference: PRV9-DN025-PFA
Technical data
| Type | Sample valve, flanged, top-entry; PTFE bellows stem seal; automatic reset closure |
|---|---|
| Sizes | DN 25 – 80 · NPS 1" – 3" |
| Pressure rating | PN 16 / Class 150 — vacuum up to 16 bar, see P-T diagram |
| Vacuum | PFA lining anchored in dovetail grooves in the body — suitable for vacuum service; limits per P-T diagram or on request. |
| Temperature | −10 °C up to +150 °C; lower and higher temperatures on request — see P-T diagram |
| Flanges | EN 1092-1 (PN 16) · ASME B16.5 (Class 150, RF) |
| Face-to-face | EN 558-1 Series 1 |
| Body | 1.0619 (A216 WCB) or 1.4408 (CF8M); clean room version 1.4408 (CF8M) electropolished |
| Lining | PFA, PFA/AS (antistatic) — PFA/UP, PVDF, PP, UHMW-PE on request |
| Stem seal | Gas-tight PTFE bellows; DIN EN 12266-1 leakage rate A |
| Bottle connection | GL connection for standard bottle DIN 168 with vent; customised connection on request |
| Options | Padlock; stainless steel safety box; customised bottle connection |
| Testing | Every valve pressure-tested in Germany before shipment. Pressure test to DIN EN 12266-1: body 24 bar, spark test on request; EN 10204 3.1 material certificates |
| Directive | Designed and manufactured to PED 2014/68/EU |
| Origin and quality | Made in Germany · country of origin Germany · ISO 9001:2015 certified manufacturing |
Materials
| Pos. | Part | Material |
|---|---|---|
| 100 | Body | 1.0619 (A216 WCB)/PFA* |
| 106 | Cover | Stainless Steel |
| 203 | Lever | Stainless Steel |
| 205 | Valve Seat | 1.0619 (A216 WCB) |
| 206 | Bellows | PTFE |
| 226 | Flange Connection | Modified PTFE |
| 302 | Guide Ring | PTFE-Carbon |
| 400 | O-Ring | FKM |
| 402 | Packing Ring | PTFE |
| 509 | Stuffing Box | Stainless Steel |
| 514 | Nut | HDPE |
| 904 | Spring Cap | Stainless Steel |
| 920 | Spring Bushing | Stainless Steel |
| 952 | Threaded Pin | Stainless Steel |
| 954 | Nut | Stainless Steel |
| 956 | Compression Spring | Stainless Steel |
Wetted parts: lining (PFA or the selected lining material), modified PTFE bellows and adapter. Further lining materials on request.
Pressure–temperature rating
Operating Pressures and Temperatures for the PFA lined Sample Valve Up to 16 bar. Lower and higher temperatures than −10 °C … +150 °C on request.
Dimensions
EN version — EN 1092-1 PN 16, EN 558 Series 1 · mm
| Size | L | H | H1 | ØD | Øk | Ød | n × ØB | Kvs m³/h (EN) / Cv (ASME)* | Sampling cone — conical / flat* |
|---|---|---|---|---|---|---|---|---|---|
| DN 25 | 160 | 190 | 123 | 115 | 85 | 68 | 4 x 14 (M12) | 15 | conical 0.385 / flat 2.56 |
| DN 40 | 200 | 250 | 127 | 150 | 110 | 88 | 4 x 18 (M16) | 47 | conical 0.385 / flat 2.56 |
| DN 50 | 230 | 195 | 131 | 165 | 125 | 102 | 4 x 18 (M16) | 65 | conical 0.385 / flat 2.56 |
| DN 80 | 310 | 310 | 173 | 200 | 160 | 138 | 8 x 18 (M16) | 200 | conical 0.385 / flat 2.56 |
ASME version — ASME B16.5 Class 150 RF, ASME B16.10 · mm
| Size | L | H | H1 | ØD | Øk | Ød | n × ØB | Kvs m³/h (EN) / Cv (ASME)* | Sampling cone — conical / flat* |
|---|---|---|---|---|---|---|---|---|---|
| NPS 1" | 160 | 190 | 123 | 108 | 79.4 | 50.8 | 4 x 15.9 | 17.5 | conical 0.448 / flat 2.98 |
| NPS 1½" | 200 | 250 | 127 | 127 | 98.4 | 73 | 4 x 15.9 | 54.8 | conical 0.448 / flat 2.98 |
| NPS 2" | 165 | 195 | 131 | 152.4 | 121 | 92.1 | 4 x 19 | 75.7 | conical 0.448 / flat 2.98 |
| NPS 3" | 200 | 310 | 173 | 190.5 | 152.4 | 127 | 4 x 19 | 233 | conical 0.448 / flat 2.98 |
* Valve Kvs in m³/h (EN rows) or Cv (ASME rows), indicative; sampling-cone values in the same unit as the row. Dimensions nominal — confirm against the certified drawing before piping design. The row of your selected size is highlighted; sizes without a row: dimensions on request.
Documents
Used in
Chemical processingFine chemicals & APIPharmaceutical & biopharmaFood & beverageChemical storage & tank farmsSulfuric acid terminals
FAQ
Questions we are often asked
PFA or PFA/AS lining?
PFA is the standard lining (virgin PFA). PFA/AS (antistatic) is for media where electrostatic charge must be led off. PFA/UP, PVDF, PP and UHMW-PE are available on request.
Which bottle connection is fitted?
A GL connection for a standard bottle to DIN 168, with vent connection. A customised bottle connection can be made to suit your existing system.
Can it be installed vertically or horizontally?
Yes, in both positions, with compatible sampling bottle adapters. The valve is top-entry, so maintenance is possible without removing it from the line.
Is the Provaron9 suitable for vacuum service?
PFA lining anchored in dovetail grooves in the body — suitable for vacuum service; limits per P-T diagram or on request.
Which documents come with each valve?
The valve is pressure-tested to DIN EN 12266-1 (leakage rate A, gas-tight) and EN 10204 3.1 material certificates are available. It is designed and manufactured to PED 2014/68/EU.
PFA or PTFE lining — what is the difference?
Both are fully fluorinated plastics with almost universal chemical resistance. PTFE cannot be melted, so PTFE liners are pressed and sintered. PFA can be melted, so we transfer-mould it into the valve body: the lining is dense, anchored in the body and follows complex shapes. If your specification says "PTFE-lined", a PFA-lined valve meets the same chemical duty — ask us for a comparison for your medium.
Related